GB/T 21412.5-2017石油天然氣工業(yè) 水下生產(chǎn)系統(tǒng)的設計和操作 第5部分:水下臍帶纜

GB/T 21412的本部分規(guī)定了臍帶纜及相關附屬設備的設計、材料選擇、制造、設計驗證、試驗、安裝和操作要求,并給出了推薦作法,用于石油天然氣工業(yè)。附屬設備不包括上部組塊硬件裝置,這些硬件是指那些在上部組塊懸掛終端之上,不與臍帶纜永久連接的設備。本部分適用于單獨的部件,如電纜、光纖、熱塑性軟管或金屬管構(gòu)成的臍帶纜,或它們組合成的臍帶纜。本部分適用于靜態(tài)或動態(tài)運行的臍帶纜,其路徑可為水上-水上,水上-水下和水下-水下。本部分不適用于相關部件接頭,除非這些接頭影響到臍帶纜或其附屬設備的性能。本部分僅適用于以下尺寸的金屬管:壁厚t<6 mm,內(nèi)徑ID<50.8 mm(2 in)。大于這些尺寸的產(chǎn)品應視為管/管道并且按照公認的管線/管道標準進行設計和制造。本部分不適用于額定壓力小于7 MPa(1 015 psi)的金屬管或軟管。本部分不適用于額定電壓高于標準額定電壓U<下標0>/U(U<下標m>)=3.6/6(7.2)kV rms的電纜,其中U<下標0>、U與U<下標m>由IEC 60502-1與IEC 60502-2定義。

BS 8490-2007虹吸排水系統(tǒng)指南

This British Standard applies to roof drainage systems usingcircular-section pipes that operate under siphonic action. It does not apply to siphonic drainage systems using rectangular or trapezoidal section conduits for water conveyance.It gives information and provides guidance on design parameters,installation, verification and maintenance needs of siphonic roofdrainage systems conforming to the performance requirementsspecified in BS EN 12056-3:2003, 6.2. Guidance is also given oncarrying out checks of designs, for the use of specifiers and regulatory authorities.Particular issues for site drainage systems that receive flows fromsiphonic roof drainage systems are also covered.

BS EN 14525-2004不同材料管道用球墨鑄鐵大公差聯(lián)接器和法蘭接頭:球墨鑄鐵、灰鑄鐵、鋼、PVC-U、PE和纖維水泥

This document specifies the requirements and associated test methods applicable to wide tolerance ductile iron couplings and wide tolerance flange adaptors intended for use with pipe components made from a number of pipe materials (ductile iron, grey iron, PE, PVC-U, steel, fibre-cement), for providing a leak tight seal over a wide range of pipe external diameters :n— to convey water (e.g. potable water);n— with or without pressure ;n— to be installed below or above ground, inside or outside buildings.nThis document is not intended to cover sewerage or gas applications, where other requirements may be necessary.nThis document specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron products.nThis standard covers ductile iron products cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 40 to DN 600, for an allowable operating pressure (PFA) up to 16 bar, for fluid temperatures between 0 ℃ and 25 ℃ excluding frost. For higher temperatures, up to 50 ℃, additional type testing should be carried out.nIt also gives performance requirements and associated test methods for restrained and non-restrained flexible joints. Joint design and gasket shapes are outside the scope of this standard.nNOTE 1 PFA may be limited depending on pipe materials effectively connected.nNOTE 2 In this document, all pressures are relative gauge pressures, expressed in bars (100 kPa = 1 bar).nNOTE 3 EN 545 gives the specifications for the ductile iron fittings to be used with ductile iron pipes.nNOTE 4 EN 12842 gives the specifications for the ductile iron fittings to be used with PVC-U and PE pipes.

BS EN ISO 21003-1-2008建筑物內(nèi)部熱水和冷水裝置用多層管道系統(tǒng).總則

This part of ISO 21003 specifies the general aspects of multilayer piping systems intended to be used for hotand cold water installations inside buildings for the conveyance of water — whether or not the water isintended for human consumption (domestic systems) or heating systems — under specified design pressuresand temperatures appropriate to the class of application (see Table 1).ISO 21003 is a reference product standard (see 3.4.3). It is applicable to multilayer pipes, fittings, their joints,and also to joints with components made of other plastics and non-plastics materials intended to be used forhot and cold water installations. This part of ISO 21003 is intended for use only in conjunction with all theother parts of ISO 21003.ISO 21003 applies only to multilayer pipes with their inner layer made of plastics.It covers a range of service conditions (application classes) and design pressures. It is not applicable forvalues of design temperature, TD, maximum design temperature, Tmax, and malfunction temperature, Tmal, inexcess of those in Table 1.NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects,taking into account their particular requirements and any relevant national regulations and installation practices or codes.The polymeric materials used for the stress-designed layers are the following: polybutylene (PB), polyethyleneof raised temperature resistance (PE-RT), crosslinked polyethylene (PE-X), polypropylene (PP) andchlorinated poly(vinyl chloride) (PVC-C).The PE-X used shall be fully crosslinked and shall comply with the requirements of the relevant referenceproduct standard (ISO 15875).NOTE 2 For the purposes of ISO 21003, crosslinked polyethylene (PE-X) as well as adhesives are considered asthermoplastic materials.Solid-wall pipes with thin outer layers (applied as protection layers or barrier layers, for instance) are notcovered by ISO 21003 but are specified in the Amendments to ISO 15874-2, ISO 15875-2 and ISO 15876-2.The total thickness of such outer layers, including the thickness of the adhesives used, shall be u 0,4 mm.

BS EN ISO 21003-2-2008+A1-2011建筑物內(nèi)冷熱水裝置用多層管道系統(tǒng).管道

This part of ISO 21003 specifies the characteristics of pipes for multilayer piping systems intended to be usedfor hot and cold water installations inside buildings for the conveyance of water — whether or not the water isintended for human consumption (domestic systems) or heating systems — under specified design pressuresand temperatures appropriate to the class of application (see Table 1 of ISO 21003-1:2008).It also specifies the test parameters for the test methods referred to in this part of ISO 21003.ISO 21003 is a reference product standard. It is applicable to multilayer pipes, fittings, their joints, and also tojoints with components made of other plastics and non-plastics materials intended to be used for hot and coldwater installations. This part of ISO 21003 is intended for use only in conjunction with all the other parts ofISO 21003.ISO 21003 covers a range of service conditions (application classes) and design pressures. It is not applicablefor values of design temperature, TD, maximum design temperature, Tmax, and malfunction temperature, Tmal,in excess of those in Table 1 of ISO 21003-1:2008.NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects,taking into account their particular requirements and any relevant national regulations and installation practices or codes.The polymeric materials used for the stress-designed layers are the following: polybutylene (PB), polyethyleneof raised temperature resistance (PE-RT), crosslinked polyethylene (PE-X), polypropylene (PP) andchlorinated poly(vinyl chloride) (PVC-C).The PE-X used shall be fully crosslinked and shall comply with the requirements of the relevant referenceproduct standard (ISO 15875).NOTE 2 For the purposes of ISO 21003, crosslinked polyethylene (PE-X) as well as adhesives are considered asthermoplastic materials.Solid-wall pipes with thin outer layers (applied as protection layers or barrier layers, for instance) are notcovered by ISO 21003 but are specified in the Amendments to ISO 15874-2, ISO 15875-2 and ISO 15876-2.The total thickness of such outer layers, including the thickness of the adhesives used, shall be ≤ 0,4 mm.